Specifications:
Characteristic | Value |
---|---|
Model | CN7006MP-RM |
Capacity | 6000 VA / 5400 Watts |
Normal Voltage | 220/230/240Vac [L+N+PE] |
Operating Voltage Range | 110-286Vac |
Operating Frequency Range | 40-70Hz (50/60Hz Auto-Sensing) |
Power Factor | 0.99 |
Bypass Voltage Range | Max: 220V: +25% (optional +10%, +15%, +20%) |
230V: +20% (optional +10%, +15%) | |
240V: +15% (optional +10%) | |
Min: -45% (optional -20%, -30%) | |
Bypass Frequency Range | ±10% |
ECO Range | Same as the bypass |
Generator Input | Support |
Output Voltage | 220/230/240Vac |
Output Power Factor | 0.9 |
Voltage Regulation | ±1% |
Frequency (Line mode) | 50/60Hz ±0.1Hz |
Frequency (Batt mode) | 50/60Hz ±0.1Hz |
Current Crest Ratio | 3:1 |
Harmonic Distortion (THDv) | ≤3% with linear load, ≤5% with non-linear load |
Efficiency | 92% |
Battery Voltage | 216/240Vdc (16/18/20pcs) |
Backup Time | Depends on the capacity of external batteries |
Typical Recharging Time | 6-8 hours (to 90% of full capacity) |
Charging Current | Maximum current 10A; charging current can be set according to battery capacity installed |
Transfer Time | Mains to battery: 0ms; Inverter to bypass: 0ms |
Protection:
Characteristic | Value |
---|---|
Line Mode Overload | Loads ≤110%: 60min; ≤125%: 10min; ≤150%: 1min; >150%: turn to bypass mode |
Bypass Mode Overload | 40A (Input breaker) |
Short Circuit | Hold whole system |
Overheat | Line mode: Turn to bypass; Backup mode: shut down UPS immediately |
Battery Low | Alarm and switch off |
Self-Diagnostics | Upon power on and software control |
Battery Management | Advanced battery management |
Indicators and Alarms:
Characteristic | Value |
---|---|
Audible & Visual Alarms | Line failure, Battery under voltage, Overload, System fault |
LED & LCD Display | Line mode, Bat. mode, Eco mode, Bypass mode, Battery under voltage, Overload & UPS Fault |
LCD Display | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
Communication Interface:
Characteristic | Value |
---|---|
Communication Interface | RS232, USB, SNMP card (optional), Relay card (optional) |
Physical and Environmental:
Characteristic | Value |
---|---|
Dimension (W x D x H) | 440 x 625 x 86.5 mm (2U) |
Weight | 16 kg |
Operating Temperature | 0-40℃ |
Storage Temperature | -25-55℃ |
Humidity Range | 20-95% (Non-condensing) |
Altitude | <1500m |
Noise Level | <55dB at 1 Meter |
IP Rating | IP 20 |
Standards:
Characteristic | Value |
---|---|
Safety | CE: IEC/EN62040-1, IEC/EN62477-1 |
EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC61000-4-11, IEC61000-2-2 |
External Battery Pack:
Characteristic | Value |
---|---|
Model | CNBC06120CR |
Battery Type | VRLA (Valve Regulated Lead Acid Battery – SMF) |
Typical Battery Recharging Time | 6-8 hours (to 90% of full capacity) |
Typical Battery Life | 3-5 years, depending on discharging cycle and ambient temperature |
System Voltage | 240Vdc |
Battery Quantity | 20 PCS |
Capacity | 9Ah/12V |
Dimension (W x D x H) | 440 x 680 x 131 mm (3U) |
Net Weight | 58/63 kg |
Operating Environment | 0℃-40℃ |
Relative Humidity | 0-95% (Non-condensing) |
Noise Level | <40dB at 1 Meter |